Slip in duct heater

Slip in duct heater. While power is disconnected, terminate all Custom heaters of either flanged or slip-in design are available with this feature (slip-in is normally preferred for ease of installation). 208V/3 Phase. 3. There are other sizing considerations that require formulas. Application. Elements employ proprietary technology known as the “Calculated Wire Temperature Method" which insures optimum heater operation at the designed electrical and temperature requirements. The opening should be 1/2" (13) wider and 1/2" (13) higher than the heating section of the heater. Insulated Terminal Box If a heater is in an air conditioning duct that runs through an un-airconditioned space, condensation may form inside the terminal box. 3) If necessary, install supports to maintain the electric heater. Control voltage for above 24V. Flanged Finned Tubular Duct Heater Max Documentation. Duct heaters are constructed using various materials, each chosen for its specific properties and suitability for different applications. Brasch manufactures UL listed open coil duct heaters specifically designed for installation to commercially rated round ducts. air velocity is required at all points across the duct heater face. 10" 4kW@208v/1 Modulating Electric Duct Heater w/wall T-stat. For ERH slip in models, cut an opening in the duct of the appropriate size that meets the 20" from smaller inlet discharge minimum as shown in (see Fig. Sized to fit the duct. ft. 2) Insert electric heater through the opening. 3) to allow the heater to slip in while maintaining a proper mounting and sealing surface. UPC: 68633461709. Diagram 1. 21. The standard size options available are AM 20, AM 25, AM 30, AM 35 and AM 40. 38 MOCP: 37. The THERMO-AIR heater is designed to complement your heating system by preheating fresh air at the lowest cost, thus continuously providing comfortable ventilation throughout the house. Incorporated in 1957 as a manufacturer of electric heaters, Warren Technology has assumed a leading role within the HVAC industry FOR SLIP-IN TYPE HEATERS ONLY: (See Fig. A variety of fin designs are available for optimizing heat transfer performance and air side INDEECO QUA Open Coil Electric Duct Heaters for Commercial Heating Applications. Instructions for Electric Duct Heaters with Type 3R Terminal Boxes. 5. When 208V/3 Phase. warrenhvac. Instructions for Field Replacement of Resistance Open Coil Elements in Brasch Duct Heaters. Patented EAS (Electronic Airflow Sensors) Open Coil Elements Options Manufacturer of direct mounted and slip-in vertical and horizontal dehumidifier electric duct heaters. They may be used as the primary source of heat or as supplementary or stand-by heat. Browse Duct Heater Model # EDHS4800, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stand This option is available for all heaters (Slip-in, flanged and round collar) of small dimensions. Warren Technology heaters are unique in their element selection and design. N/A Current Draw: 17. 19. Automatic reset prevents overheating. Be sure the airflow switch reference port (opposite to the sensing port) is open to the atmosphere. Maximum Size 36 x 36 in. HVAC Insulated-Flex Ducting 8-in x 300-in Insulated Aluminum Flexible Duct R 3. The following materials are commonly used in duct heater construction. Square to round sheet metal transitions. Heater Section available as Slip-In or Flanged Mount. Galvanized steel standard; stainless steel optional. Number of Heating Stages: Single and three-phase QUZ heaters are available with multiple heating stages IDHB IDHE. Thermolec Open Coil heaters are designed for use in all forced air commercial and industrial HVAC systems. Try changing the heater to flanged design which should help when you are at threshold of the maximum kW per square foot of a slip-in heater. DUCT HEATER DUCT HEATER INSTALLING WITH HEAT PUMP OR CENTRAL AIR CONDITIONER INSTALLING IN BRANCH DUCT TAKE-OFF FIGURE 1 FIGURE 3 FIGURE 4 FIGURE 2 INSTALLING NEAR AIR HANDLER DISCHARGE 2. Construction For Lined Ducts All Indeeco slip-in heaters are suitable for use in ducts lined with up to 1″ (25. Flanged Heater-Removable Heater Section. CSA and UL listed. Their applications vary from a partial or auxiliary nature to being the principal heat source in a building. 07" WC to close the switch before the heater will operate. x 25 ft. 233 Series Core Replacement. It is designed so that the frame dimensions are slightly smaller than duct dimensions. 6" & 8" Duct Sizes. These roll-formed flange profiles are made using high quality grade Galvanized Sheet Metals. Electrical Specifications Note. Disconnecting contactors meet UL requirements for remote location. Our heaters are factory-assembled and wired for the electrical specialties and controls of each project, and are available with round duct connection collars. Duct sensor The DS-600 is a thermistor based duct sensor designed to work with Thermolec’s thermostats and electronic controllers to modulate the heater’s capacity according to the heat required. Coast Guard Requirements for shipboard use (Figure 54). Voltages 120/1 - 480/3 120/1 - 480/3 Capacity 18 kW per sq. This hole should be 1/8” (3. Features vary depending upon model and include automatic high limit switches, 24 V transformers, pilot relays, grounding lugs, hinged covers, wiring Singular Open Coil Duct heaters are designed to produce at least 22. From Slip-in to Flanged Mounted Designs Indeeco has the heater for your application. N/A. Documentation. Control Circuit Options and Special Features: QUZ heaters have various control options and a full range of special features. Figure 52. Above duct heaters can be ordered with less kW than listed, for each model if needed. Heating Density: 22. Select Department. Insulated Flexible Duct R6 Silver Jacket is used in standard Heating and Air Conditioning (HVAC) systems and some venting applications. Standard Option G features include; Automatic & Manual Resets, Airflow Switch, Magnetic Contactors, Fuse Protection,Control Transformer, & Built-in Disconnect. In most cases the DS-600 is used with Thermolec’s 0-10 VDC Room Thermostat to allow it to function as a duct stat. Whether it’s cooling off a bedroom, adding airflow to a stuffy garage, or cooling off the entrance to a mall, Marley’s line of ventilation products has the answer. 233 Series IOM. 4 mm) of interior insulation. HVAC Insulated-Flex Ducting 6-in x 300-in Insulated Aluminum Flexible Duct R 3. Heating, Air Conditioning, Ventilation and Air Distribution Products Web Line Direct Help Line 1. Convert existing Forced Air Dryers and Ovens. Slip-in or Flange. Maximum Heating Capacity: 1000 KW (single section) Large Duct Sizes and Multiple heaters can be made and field installed together to accommodate large duct sizes or Heating Capacities (KW’s). slip-in portion slides out without removing flanges from duct. The Thermolec CSA NRTL/C listing is limited to 22. 4. The . Cut a hole in the side of the duct to accommodate the body of the heater (excluding terminal box). 3719 The slip-in type electric heaters are designed so that the entire frame can be inserted into the duct. 9. When Modine’s gas-fired duct furnaces are designed for both indoor and outdoor installations. N/A Current Draw: 55. Rubber-Cal. The heater frame is attached to matching duct flanges, see fig. 1) Duct Heater Installation: The connection of the heater to the duct must be sealed with an RTV silicone/rubber material (GE 112, DOW 736, or DOW 738) to be watertight. 76 MCA: 78. 3) Secure electric Connections between Control Panel and Heater section are easily made through the use of factory installed terminals. 09. Thermolec is one of the top three custom duct heater manufacturers in North America. This hole should be 1/8” larger than the heater frame. Electric Duct Heater Owner’s Manual. 060, . No. 10. Weatherproof construction optional The standard slip-in heater ordered by nominal duct size is built and undersized to accommodate the industry predominant 1" (25) internal duct installation. Slip-in Finned Tubular Duct Heater Max. Fresh Air Heater Today's airtight homes and offices beg for fresh air. With clear instructions and detailed specifications, you'll have the confidence to maximize the performance and longevity of your Thermolec products. For safety, use hangers on larger heaters. This allows the control cabinet to be installed on either side of a horizontal duct or in any orientation on a vertical duct. Retrofits are much simpler, smaller dimension Duct Heaters 5 Slip In Heater It is designed so that the frame dimensions are slightly smaller than duct dimensions. Open Coil Electric Duct Heaters are custom engineered to customer specification and built to order. Stock-Line (SL) Electric Duct Heaters. 65. The entire heater except the terminal box slides through a rectangular opening in the side of the duct with 1/4" clearance all around. Air Flow Requirements for ON-OFF Control The minimum air flow required through a duct heater depends on the KW per square foot of face area for the highest capacity ON-OFF The standard slip-in heater ordered by nominal duct size is built and undersized to accommodate the industry predominant 1" (25) internal duct installation. THIS HEATER HAS BEEN REPLACED WITH TUTCO EDH MULTI-POSITIONAL DUCT HEATER. Round Duct Construction. One of the advantages of open coil heaters is that a number of similar heaters can be attached with one another to accommodate large duct size. Your supplier of choice since 1973, Thermolec designs and manufactures electrical heating equipment, modulating controls and steam humidifiers. 233 Series Pole Slip-on Flanges. The only thing to make sure is that the duct heaters being used have similar voltage needs. TPI HOT POD In-Line Duct Heater. Nailor Electric Duct Heaters are self-contained heating units designed for installation in air handling systems. Step 3. With three-phase, each heating stage features a multiple of three elements to deliver a balanced three-phase load. Heaters are available for installation to spiral single and double wall or snaplock round sheet metal ducts with inside diameters of 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 and 28 inches. 2. 2) Secure electric heater by using metal screws through round flanges. Above specifications for all horizontal DCA 407C and 410A series Air-Cooled Non Water Heating and Water Heating Assist Dehumidifiers, unless otherwise specified by. 22 Slip-in Heaters 22 Flanged Heaters 22 Zero Clearance Construction 23 Physical Standards Standard Duct Heaters – Open Coil 24 QUA Slip-in and QUZ Flanged Heaters 24 KW Ratings 24 Frame Sizes 25 Sizes and Maximum KW Ratings 26 Detail Dimensions 26 Voltage and Phase 26 Control Circuit Options & Special Features 26 Number of Heating Stages Duct and Dampers. 79 MCA: 173. The following formulas can be used to determine the maximum kW for heater frame sizes. TUTCO DHC 120V - 480V Electric Duct Heater - 3 Phase / 1 & 2 Stage. All units include primary and secondary thermal protection and are designed for use with vertical or horizontal DUCT HEATERS UL & CSA LISTED ELECTRIC DUCT HEATERS STOCK- LINE SERIES • QUICKSILVER SERIES • CUSTOM BUILT SERIES WARREN T E C H N O L O G Y, I N C 2050 West 73 Street Hialeah, FL 33016 • Telephone: (305) 556 -6933 • Fax: (305) 557 -6157 Website: www. Slip-in also available, if necessary, to match other equipment. 3mm) more than the frame width ‘’D’’. Stock-Line units are UL listed and meet the requirements of the National Electric Code (NEC). Jun 27, 2023 · Material Selection for Duct Heaters. To install a slip in heater, cut an opening in the side of the duct. Most popular in the industry. 5mm) wire mesh screen may be mounted on both sides of the heater. These instructions are for IDHE-O heater that are designed for and will be used in outdoor installation. Finned tube and open coil styles are available and can be custom designed up to 1000 KW, in slip-in or flanged configurations, with galvanized steel frame and terminal box constructions. 2. Modine offers multiple 460V/3 Phase. 257. N/A Current Draw: 25. Thermolec website. CLICK HERE FOR EDH DUCT HEATER. 045 Construction W x H Minimum Size Maximum Size Slip in Heater Flange Heater Inches 8 x To arrive at the heating capacity required in your home, you should use the formula. Remove heater and drill mounting holes. 08. The IDHE series is the industry’s first and only electric duct heater approved by UL for multiple mounting positions. Slip-on Flanges are key components of 4-Bolt duct connectors system. Technical Description: 16 Inch W X 10 Inch H Size; 3 Phase (S); UL Approval; 208 V Voltage Rating; Wall Mounting; 27. The Neptronic slip-in heater has a standard 1" (25. Posted on September 29, 2022 | Read More Manual del usuario del calentador de conductos Ultra-safe Duct Heaters Browse Duct Heater Model # EDHS3000, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stand Each electric duct heater's unique design allows air to flow freely for the lowest possible pressure drop. 27. The 3/8″ (9. Part No: ZON-10-4208. Primary applications are for building heating, cooling and make-up air systems. In addition to online quoting, you can call our quoting specialist at 1-800-327 Flange & Slip 'n' Type. The control cabinet is offset from the heating elements similar to traditional heaters. Add All Cart. 2 product. Allow ¼’’ (6. foot 30 kW per sq. Air pressure in the duct must be at least 0. 7. Marine Duty – Only Indeecooffers a ULListed duct heater which is also ABS Design Assessed and meets U. Slip the heater into the duct and attach the back of the terminal box to Marley Engineered Products has a complete line of air circulators, air curtains, portable blowers, and ceiling fans for every application. Ventilation. To install INDEECO flanged duct heaters, flanges must be provided on the duct to match the heater flanges, both on the entering and leaving air sides. Insert heater until terminal box covers opening. Career Opportunities; Thermolec Electric Duct Heaters. All heaters are maysuitable for installation with zero spacing between the duct and combustible surfaces. Baseboard Features. foot Minimum Size 8 x 8 in. the notes below. To aid in providing this minimum air velocity, follow the mounting limitations as follows. Our comprehensive product documentation provides all the essential information you need for seamless installation, operation, and maintenance. com Duct heaters are traditionally used in forced air systems to provide standalone space heat or to supplement existing heating systems. Booster coils are provided with a variety of casing configurations, including fully flanged, slip and drive, or end plates only. 2) 9. Both standard and quick ship delivery programs are available for the full line of HUA and HUP heaters. It can be a new installation or can be integrated into your forced-air systems as a primary or secondary/auxiliary heat source. Electric Duct Heaters. 8 x 8 in. N/A Current Draw: 62. Heaters. Slip-in or Flanged configurations with heavy gauge galvanized steel frame and terminal box construction. Booster Heater in Process and Comfort Heating Ducts. 3,000. the Duct outlet to Duct Inlet ratio cannot exceed 4:1. 81 View Product. 74 MOCP: 26. In addition, this heater is rated for slip in application only. Warren offers custom duct and standard unitary slip-in heaters to meet electric heating specification and design requirements. 1. Square Duct Heater Height Square Duct Heater Width Inside Round Duct Diameter Figure 53. The heaters are shipped loose, can be duct-installed onsite and are designed 10" 3kW@240v/1 Modulating Electric Duct Heater w/wall T-stat. Slide the heater into the duct. Control Volts 24-277. Secure heater in place with sheet metal screws. Standard Volts 120-480 / 1 & 3 Phase. common materials used in duct heater construction. 3 Heater Control Stage Pneumatic Heater Type Slip in Flange Heater Voltage/ Phase 120/1 208/1, 208/3, 230/1, 230/3, 277/1, 460/1, 460/3, 480/1, 480/3 Material Galvanized Steel - Recess (in. 14. Slip the heater into the duct and attach the back of the terminal box to the duct with sheet metal screws. User Manual – Process Air Heaters. 6. The Master Flow 16 in. HUA and HUP heaters are available up to 456 KW. ) None 1, 2 Control Transformer None Unfused Deration (kW) None. When installed, the face area of the heater is at right angle to the air stream. Page 2 continued installation etc. HVAC Insulated-Flex Ducting 4-in x 300-in Insulated Aluminum Flexible Duct R 3. The THERMO-AIR heater is a quality product engineered for peak performance, low operating cost and long life. 227 Series IOM. 39 MCA: 21. $901. Any voltage desire, that is not listed, please contact factory. Be sure the airflow pickup tube has been turned into the air stream. 1 MCA: 31. 460V/3 Phase. Integrated HEC controller. All construction features of the Custom Built heaters are incorporated in the Remote Panel Heater. Unit Heaters. INDEECO QUA Open Coil Electric Duct Heaters for Commercial Heating Applications. Chromalox Air Duct Heater CAB-611 240V 6KW. Advantages of slip-in electric heaters: A system using a slip-in heater permits the installation of the entire ventilation duct system before the heaters become available. 4mm) flange on each side of the controlbox and can be attached directly to the duct with sheet metal screws. Stainless Steel. Cut hole in side of duct 1/8” larger than heater body. To install, cut an appropriate sized opening in the duct to allow the heater to tightly slip in. Price: $1,087. 120 x 144 in. • Process Heaters for applications requiring a high discharge temperature up to 1200ºF (649ºC) with proven standards • Heaters to fit in air handling and make-up air units • Specially designed for large kW and dimensions Enclosure Types Neptronic’s selection of electric heaters includes tubular, open coil, zone, and dual-energy plenum heaters. 440 F Max. A variety of thermostats and sensors are available. This can be done by multiplying the airflow rate (cubic feet per minute or CFM) by the temperature rise (in degrees Fahrenheit) and then dividing by 3. FOR SLIP-IN TYPE HEATERS ONLY: (See Fig. Continuing R&D coupled with our skilled and experienced design engineers helps make our products trouble-free. TPI HOT POD In-Line Duct Heater HIGH CAPACITY. 5 KW per square foot of duct area; Maximum Applicable Voltage: 600 V / 3 Phase; Primary Thermal Protection: Auto Reset disc cut out Browse Duct Heater Model # EDHS2000, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stand Description: TPI 8PD1018103 10Kw 208V 3 Phase Packaged Duct Heater. They are strategically placed and controlled for zone comfort heating. 230V/1 Phase. Step 1. Browse Duct Heater Model # EDHS14000, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stan 22 Slip-in Heaters 22 Flanged Heaters 22 Zero Clearance Construction 23 Physical Standards Standard Duct Heaters – Open Coil 24 QUA Slip-in and QUZ Flanged Heaters 24 KW Ratings 24 Frame Sizes 25 Sizes and Maximum KW Ratings 26 Detail Dimensions 26 Voltage and Phase 26 Control Circuit Options & Special Features 26 Number of Heating Stages Jun 9, 2023 · The first step in determining the appropriate heater size for your duct heater is calculating the required wattage. TPI HOT POD High Capacity In-Line Duct Heater. 93 each. 99 each. INDEECO slip-in duct heaters are installed by inserting through a rectangular opening cut in the side of the ductwork and are secured to the duct with sheet metal screws. TPI HOT POD In-Line Electric Duct Heater. The resulting number is the required wattage. Browse Duct Heater Model # EDHS4100, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stand About This Product. NEW EXPANDED RANGE; CAPACITIES FROM 1 to 12 KW; FITS FROM 5" TO 12" DIAMETER DUCTS; BUILT-IN ADJUSTABLE ELECTRONIC DUCT SENSOR 0°C to 42°C (32°F to 108°F) JUST ONE ELECTRICAL CONNECTION AND THE UNIT IS READY TO PERFORM 20”. Be sure that the positive port has been connected when the heater is on Duct Heaters. Price: $503. The entire heater except the terminal box slides through a rectangular opening in the side of the duct with ¼ clearance all around. Wireless & Corded option. Part No: ZON-10-3240. Control Volt 24-277. Step 2. Stock-Line slip-in type duct heaters ship 4 business days after order placement. . These heaters consist of a slip-in type mounted in a flanged Thermolec In-Line Duct Heaters: Units equipped with a highly advanced electronic modulating controller and air flow sensor to minimize operating cost. Fan Assisted. Above specifications for all DCA series Air-Cooled & Water-Cooled units. Brasch has developed HUA and HUP heater lines to satisfy most typical space heating requirements, simplifying specification, ordering and delivery. SCFM x temperature rise (°F) kW = ———————————– x 1. Available with integrated sealant applied in profiles. Neptronic offers duct heaters with customizable sizes and heating capacities to match existing ductwork. STANDARD OPEN COIL DUCT HEATERS. Sort & Filter (1) List. 2 Stage - Zero Clearance. 5 to 1000kW (larger loads also available) Up to 40kW per sq. 175mm) larger than the heater frame. Slip-in heaters are designed so that the entire frame, except the terminal box, slips into the duct with ¼ inch clearance all around. TUTCO DHC Electric Duct Heaters. the duct to allow the heater to tightly slip in. Some heaters are an integral part of other equipment, some have been approved for direct attachment to other equipment such as heat pumps, fans and variable air volume terminals, while others are approved for use as complete heating units to be mounted in air ducts. 888. This additional insulation provides greater thermal efficiency Standard Duct Heaters – Open Coil 28 HUA Slip-in and HUP Flanged Heaters 28 KW Ratings 28 Frame Sizes 29 Sizes and Maximum KW Ratings 30 Detail Dimensions 30 Voltage and Phase 30 Control Circuit Options & Special Features 30 Number of Heating Stages 31 Special Features 35 HUA/HUP – Sample Specification Custom Duct Heaters Warren Technology has provided electric heating equipment for more than 60 years. Slip-in type electric heater - Type I 1) Cut an opening in the duct. 8 Ampere Current Rating; 10 kW Power Rating; Magnetic Contactor, Step Down Control Transformer Control Type; Galvanized Steel Heating Element. Available in gravity vented, power vented, and separated combustion configurations, Modine has duct furnaces to service a wide range of applications. 2) 8. Controls Staged Staged SCR Pneumatic Vernier SCR Pneumatic Thermostat Room Room Duct Rotatable No Yes Airflow Direction Horizontal Horizontal Vertical Up Vertical Up Vertical Down obstructions around the duct. 120 volt single phase. 12”. com • E-Mail: warren@warrenhvac. Standard flanged design recommended to support heater weight. Remove the heater and drill mounting holes. Open Coil heater with round duct transitions. Control Enclosure NEMA 7, 9 cast aluminum box with hinged cover houses controls and element terminals. For instance, to find the BTUH required, calculate as follows: BTUH = Temp rise x CFM x 1. NEW EXPANDED RANGE; CAPACITIES FROM 1 to 12 KW; FITS FROM 5" TO 12" DIAMETER DUCTS; BUILT-IN ADJUSTABLE ELECTRONIC DUCT SENSOR 0°C to 42°C (32°F to 108°F) JUST ONE ELECTRICAL CONNECTION AND THE UNIT IS READY TO PERFORM Sep 29, 2022 · Read More Duct Heaters Owner’s Manual Duct Heaters Owner’s Manual – English & French. Page 1 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR INDEECO ELECTRIC DUCT HEATERS APPLICATION INFORMATION Slip the heater into the duct and attach the back of the terminal box to Follow the procedure given on the reverse side of this sheet the duct with sheet metal screws. S. 41. Re-insert the heater and mount to the duct using sheet metal screws. duct. 52 View Product. Available with single phase, 230 V power supply and 4 kW to 50 kW electric heating capacity. N/A Current Draw: 138. kW = Width X (Height – 2) X 0. INDEECO slip-in duct heaters are installed by inserting through a rectangular opening cut in the side of the duct work and are secured to the duct with sheet metal screws. Insert the heater and use the heater box as a template for the mounting screw locations. Slip the heater into the duct and attach the back of the terminal box to Open Coil Electric Heaters. FLANGED HEATER (Optional) Consists of a slip-in heater mounted in a flanged duct section. Heatcraft ® Duct/Booster coils are duct-mounted reheat coils used with hot water or steam for general heating applications. When we trap the heat, excess humidity and indoor pollutants such as cleaning products, smoking and pets, will negatively affect the quality of the air we breathe, making our environment both uncomfortable a Figure 52. 5 KW per square foot of duct area for open coil heaters and 13 KW per square foot of duct area for tubular element heaters. These heaters are designed in such a way that the frame dimensions are slightly smaller than duct dimensions. Transformer T1 Class II, 1-3 stages (default) T2 Class II, 4 stages + T3 Class II, Resettable T4 Primary Fused, 1-3 stages T5 Primary Fused, 4 stages + OO None The THERMO-AIR heater is a quality product engineered for peak performance, low operating cost and long life. Posted on September 29, 2022 | Read More Duct Heaters Owner’s Manual – English & French Manual del usuario del calentador de conductos. 52 MCA: 69. Suitable for most standard HVAC ducted systems Heating capacities from 0. 059. 1 Single phase models only. Two 6″ duct models: 1kw, 2kw. Left or Right Offset Control Box. Use the holes in the controls box as a template for locating the mounting holes in the duct. All. 45 MOCP: 94. 5 KW per square foot area. Finned tubular duct heater construction may be more appropriate for these applications. 49 MOCP: 208. The duct has R6 insulation which contains 33% more insulation than the standard R4. 3) Secure electric All heaters are maysuitable for installation with zero spacing between the duct and combustible surfaces. Control Voltage for above -24 volts. $951. 4 MOCP: 83. Flanged heaters are designed so that the heater is an integral part of the duct work. Features and applications of the CAB Air Duct Heater: Sole Heat Source. With Blower and Duct, can be used to Fabricate simple Forced Air Drying Unit. lh pd jo gu rp vc fk jz xh zd