Slip in duct heater. It can be a new installation or can be integrated into your forced-air systems as a primary or secondary/auxiliary heat source. This is the Hydronic Duct Heating & Cooling Coils. Slip-in Finned Tubular Duct Heater Max. TUTCO EVH VAV Single Duct Reheat Electric Heater. These instructions are for IDHE-O heater that are designed for and will be used in outdoor installation. The heater frame is attached to matching duct flanges, see fig. The controls enclosure shall be NEMA-1 construction with a removable cover. • When an airflow switch is used as a fan interlock, the heater will contain an air pick-up probe. TUTCO E-Series Duct Heaters have higher duct to heat coverage, and more kilowatt options compared to the Booster Coils. Slip the heater into the duct and attach the back of the terminal box to How to disassemble slip and drive hvac. Canada-Wide shipping ( 1-5 day delivery on most orders ) (see shipping estimates in shopping cart) Ships in : 2 - 5 Established in 1929, Indeeco designs and manufactures highly-engineered electric heating and thermal management technologies for commercial and industrial markets and also for military, marine and rail applications throughout North America and abroad. The E-Series Flip-Able Duct Heater has been specifically designed, developed and tested with symmetry in mind. Hydronic duct heating and cooling coils use hot or chilled water to produce supplementary warm or cool air. Indeeco is based in St. Thermolec Duct Heater Model TER-ZON. Do not install a heater marked for horizontal airflow in vertical duct or a vertical heater in horizontal duct. IDHB & IDHC Two frame types are available: • Slip in - allows you to slip the heater into the opening in the ductwork. 14 × 10 × 14 in. Fan Assisted. 3 Warren Technology heaters are unique in their element selection and design. Booster coils are provided with a variety of casing configurations, including fully flanged, slip and drive, or end plates only. Consult the factory for optional solutions. Re-insert the heater and mount to the duct using sheet metal screws. 10. (square foot) of duct area, divide the total watts required by the duct size (Watt density = watts/duct area (ft2). No. The minimum airflow through a duct heater is directly related to the inlet air temperature. Unlike open coil designs, duct heaters fitted with tubular elements are not Documentation. Remove heater and drill mounting holes. 5 KW per square foot area. All coils have 5/8-inch OD copper tubes, . The Thermo-Air (TER) and Thermo-Zone (ZON) electric duct heaters are unique to Thermolec. Insulated Flexible Duct R6 Silver Jacket is used in standard Heating and Air Conditioning (HVAC) systems and some venting applications. They're used in both replacement and new construction applications in large commercial buildings. com or call us directly at 800-243-8162. The Neptronic slip-in heater has a standard 1" (25. Maximum 6″ thick lining. 120 volt single phase. Heatcraft ® Duct/Booster coils are duct-mounted reheat coils used with hot water or steam for general heating applications. Stock-Line slip-in type duct heaters ship 4 business days after order placement. Dimensions. Slide heater in the duct using the control box as template to mark the mounting screw holes. Duct Heater. Our comprehensive product documentation provides all the essential information you need for seamless installation, operation, and maintenance. Two 6″ duct models: 1kw, 2kw. This is conservative enough to ensure a long service life. TPI Corp. Wireless & Corded option. All units include primary and secondary thermal protection and are designed for use with vertical or horizontal 6 days ago · Marley Engineered Products has a complete line of air circulators, air curtains, portable blowers, and ceiling fans for every application. The duct has R6 insulation which contains 33% more insulation than the standard R4. Max height of 144” and max width of 120”. 5 KW per square foot of duct area for open coil heaters and 13 KW per square foot of duct area for tubular element heaters. ) Nordfab Quick-fit duct system. Unheated Sections. 233 Series Pole Description: TPI 8PD1018103 10Kw 208V 3 Phase Packaged Duct Heater. Process Air Heaters. Stock-Line units are UL listed and meet the requirements of the National Electric Code (NEC). The control cabinet is offset from the heating elements similar to traditional heaters. the design of the thermal cutout system make standard slip-in heaters suitable for such installations without any deterioration in performance or life. A variety of thermostats and sensors are available. Neptronic’s selection of electric heaters includes tubular, open coil, zone, and dual-energy plenum heaters. Variable CFM requirement based on inlet air temp. 5 to 1000kW (larger loads also available) Up to 40kW per sq. Baseboard Indeeco is a leading manufacturer of thermal heating solutions for various applications and industries. Both are available with 6” – 12” round duct connections and up to 12 kW of electric heat in single phase power. Highest KW options. Inspect the duct work to make sure the area is free of obstacles and wiring before cutting the mounting hole. All construction features of the Custom Built heaters are incorporated in the Remote Panel Heater. This particular type of heater can be inserted or displaced,so it’s sometimes known as the unit heater. This one heater may be installed in four different positions eliminating the need for different right and left handed designs. Warren Technology has provided electric heating equipment for more than 60 years. labels. Hot water and steam booster coils are available in one- or two-row configurations. To calculate the watts per sq. Your supplier of choice since 1973, Thermolec designs and manufactures electrical heating equipment, modulating controls and steam humidifiers. Approvals Heaters and panelboards (if required) shall meet the requirements of the National Electrical Code and shall be listed by Underwriters Laboratories for zero clearance to combustible surfaces and for use with heat pumps and air conditioning equipment. 2) Insert electric heater through the opening. The only thing to make sure is that the duct heaters being used have similar voltage needs. Sep 29, 2022 · ULTRA-SAFE™ Explosion-proof Duct Heaters. This is rectangular style hvac. Insulated Terminal Box If a heater is in an air conditioning duct that runs through an un-airconditioned space, condensation may form inside the terminal box. From VAV systems, duct heaters, hazardous location unit heaters, or residential wall heaters; Redd-i Products Company has a solution for your comfort conditioning requirements. Posted on October 14, 2022 | Read More ULTRA-SAFE™ Explosion-proof Duct Heaters Custom Duct Heaters. Flip-Able design, airflow in any direction, designed for zero clearance. The standard slip-in heater ordered by nominal duct size is built and undersized to accommodate the industry predominant 1" (25) internal duct installation. In addition to online quoting, you can call our quoting specialist at 1-800-327 Duct heaters are traditionally used in forced air systems to provide standalone space heat or to supplement existing heating systems. 233 Series IOM. Posted on October 14, 2022 | Read More Custom Duct Heaters Duct Heaters Owner’s Manual. TPI HOT POD In-Line Duct Heater HIGH CAPACITY. DUCT HEATERS – DH – SLIP IN TYPE DH – B-10 / 20, Galvanized / Stainless steel Construction. Above specifications for all horizontal DCA 407C and 410A series Air-Cooled Non Water Heating and Water Heating Assist Dehumidifiers, unless otherwise specified by. 8 Ampere Current Rating; 10 kW Power Rating; Magnetic Contactor, Step Down Control Transformer Control Type; Galvanized Steel Heating Element. 7. ft. Singular Open Coil Duct heaters are designed to produce at least 22. Unit heaters are efficient for house and commercial buildings since its simple design makes it easier to remove for maintenance and cleaning. Heaters. For safety, use hangers on larger heaters. Disconnecting contactors meet UL requirements for remote location. P. 2. Both units come with an electronic airflow sensor and duct temperature sensor. Circulation & In-Line Heaters. Slip-in or Flanged configurations with heavy gauge galvanized steel frame and terminal box construction. Some exceptions apply 1-866-361-4782 Start Your Project; Limit electric heater consumption based on multiple variables; Provides real-time temperature measures and power consumption data; Save Time. Seal heater control. Voltage Rating :110 V / 220 V / 400 V Models:DH-B-10 ; DH-B-20 . Duct Internal Insulation. Custom heaters of either flanged or slip-in design are available with this feature (slip-in is normally preferred for ease of installation). Browse Duct Heater Model # EDHS3000, Electric Duct Heater in the Dehumidifier Corporation of America catalog including Dehumidifier Model #s,Duct Heater Model #,Item Name,Description,Add on Electric Heating Capacity,Stages,Duct Dimensions W x H,Stand . Standard low watt density coil Limitations The Open Coil Electric Duct Heater is designed for indoor ductwork installation only. Thermostat - Room stat: controls heater to maintain adjustable space temperature when heater is used as primary heating method. Price: $1,087. obstructions around the duct. - Duct stat: controls heater to maintain adjustable discharge temperature. Mount unit to duct with sheet metal screws. mfg # sl5a. Neptronic offers duct heaters with customizable sizes and heating capacities to match existing ductwork. • Flange - allows you to bolt into place between two sections They can build any size and any configuration of electric duct heater. MARKEL290289. Coils in a flanged casing mount in air-handling units or to ductwork, while coils in a slip and drive duct. 52 View Product. For ERH slip in models, cut an opening in the duct of the appropriate size that meets the 20" from smaller inlet discharge minimum as shown in (see Fig. Free Shipping on orders over $300. Type HUP Custom Flanged Heater. INDEECO slip-in duct heaters are installed by inserting through a rectangular opening cut in the side of the ductwork and are secured to the duct with sheet metal screws. Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. This additional insulation provides greater thermal efficiency Document 484166 Model IDHE-O Outdoor Applications. com ELECTRIC DUCT HEATERS - GENERAL INFORMATION ELECTRIC DUCT HEATERS TYPES SAFID electric duct heaters series “EHO”, “EHT” and “EHFT” are designed for a trouble free operation at a competive price. Fin heights up to 24-inches. 3mm) more than the frame width ‘’D’’. Tubular & Finned Tubular Elements. 30 lbs. Electric Duct Heaters are custom designed to the most stringent UL-1996 standard to assure total safety. Flanged Finned Tubular Duct Heater Max the design of the thermal cutout system make standard slip-in heaters suitable for such installations without any deterioration in performance or life. Inlet/Outlet. 059. When the Duct outlet to Duct Inlet ratio cannot exceed 4:1. Standard Option G features include; Automatic & Manual Resets, Airflow Switch, Magnetic Contactors, Fuse Protection,Control Transformer, & Built-in Disconnect. When we trap the heat, excess humidity and indoor pollutants such as cleaning products, smoking and pets, will negatively affect the quality of the air we breathe, making our environment both uncomfortable a electric duct heater slip-in 240 vac 1-phase, 20 a, 5 kw. Weight. Explosion-Proof Screw Plug Immersion Heaters. The Duct heaters casing are as standard in 1. 12”. part # sl5a. 81 View Product. Incorporated in 1957 as a manufacturer of electric heaters, Warren Technology has assumed a leading role within the HVAC industry, designing, developing, and manufacturing a broad spectrum of precision heating Heater installation & preparations 1. Allow ¼’’ (6. 3) to allow the heater to slip in while maintaining a proper mounting and sealing surface. Accessories/Options All are separate accessories depending on configuration. For most low and medium pressure jobs, Duct Manufacturer: Thermolec Description: Electric In-Line Duct Heater 6" - 2kw Compatibility: Any Air Exchanger Minimum Air Flow Required: 60 cfm Manufacturers' Part Number: Ter-6-2120 Purchase Includes Unlimited Technical Support. Be sure that the duct dimensions specified are those inside the duct lining. A variety of fin designs are available for optimizing heat transfer performance and air side duct. Open Coil Electric Heaters. Duct Heaters TUTCO manufactures efficient Electric Duct Heaters for every heating application. 2) Secure electric heater by using metal screws through round flanges. To install, cut an appropriate sized opening in the duct to allow the heater to tightly slip in. Continuing R&D coupled with our skilled and experienced design engineers helps make our products trouble-free. All heaters shall be furnished with a disc type, Rectangular Flange Heaters. In most cases the DS-600 is used with Thermolec’s 0-10 VDC Room Thermostat to allow it to function as a duct stat. The Flat S Lock is hammered onto the section on right. Above duct heaters can be ordered with less kW than listed, for each model if needed. (ø 100-500 mm. Impedance Pipe Heating Systems. Technical Description: 16 Inch W X 10 Inch H Size; 3 Phase (S); UL Approval; 208 V Voltage Rating; Wall Mounting; 27. 2 Stage - Zero Clearance. 2) 9. Little Giant Baptistery Electric Circulation Heater ONLY (No Pump) with High Limit Protection - 6000 Watt - 25 Amps - Adjustable thermostat 60F-107F - 27" x 21 3/8" x 5 1/2" - 1" F. This hole should be 1/8” (3. Cut a hole in the side of the duct to accommodate the body of the heater (excluding terminal box). Warren offers custom duct and standard unitary slip-in heaters to meet electric heating specification and design requirements. This duct heater can be mounted in multiple positions like the IDHE. We designed these heaters for easy installation into a duct either in slip-in insert type or in flagned type as to meet with the Select Department. (Markel/Raywall/Fostoria) Hotpod Supplemental Inline Duct Heating System, 120V, 1 Phase, 1000W, 6" Duct Size, Included: Plug & 10ft Cordset, RFKit5, Outlet & Return Air Grill, Two 90 degree Elbows, & Two Flexible Duct Sections, Catalog #: 029. Used in ducts lined with more than 1″ thick interior insulation. It requires field adjustment for specific job requirements. 006 aluminum fins, and one-inch flanged or slip and drive galvanized casings in four-inch depth. 6" & 8" Duct Sizes. Screw Plug Immersion Heaters. For more information about the installation of our electric duct heaters – flange or slip-in mounting – please visit us online at www. 3) If necessary, install supports to maintain the electric heater. Duct heaters shall be Heatrex Type HUA Custom Slip-in Heater Type HUP Custom Flanged Heater. 233 Series Core Replacement. The clip has an inner gasket to ensure that an air tight seal is achieved. C. The electric heater frame will have flanged or slip-in duct connection. They consist of a heating element which converts electricity into heat through Resistance – the process by which Connections between Control Panel and Heater section are easily made through the use of factory installed terminals. Patented EAS (Electronic Airflow Sensors) Open Coil Elements Options Insulated Duct Construction for Slip-in Heaters. All heaters are maysuitable for installation with zero spacing between the duct and combustible surfaces. CSA and UL listed. Built in the USA, we work hard to earn your respect Oct 31, 2018 · Slip & Drive Duct Installation. Jan 23, 2015 · Finally, either of these electric duct heater options can be custom-built for any size duct and for any unusual placement or installation. Open Coil Electric Duct Heat slip in model duct heaters for horizontal and vertical applications. Applications Greenheck duct heaters are used in forced air applications to provide dedicated space heat or to supplement existing Open the catalog to page 2. The components have a rolled collar,over which the Nordfab Q-F clip is fitted. The Drive Cleat is secured to the 360 degree flanged section on left (formed by a Cleatbender or Drive Turn machine). Face Size Range: 6” x 6” up to 144” x 96”. x 25 ft. Posted on September 29, 2022 | Read More Duct Heaters Owner’s Manual Duct Heaters Owner’s Manual INDEECO slip-in duct heaters are installed by inserting through a rectangular opening cut in the side of the duct work and are secured to the duct with sheet metal screws. Do not install a slip-in or flanged heater intended for side mount on the top or bottom of horizontal duct. 5. 6. Replacement Boiler Flange Heaters. Thermolec manufactures tubular element heaters for applications which involve personnel safety or critical conditions in the duct such as high humidity level, combustible dust or corrosive atmosphere. Finned tube and open coil styles are available and can be custom designed up to 1000 KW, in slip-in or flanged configurations, with galvanized steel frame and terminal box constructions. indeeco. The Thermolec CSA NRTL/C listing is limited to 22. UPC: 68633461709. Features. Suitable for most standard HVAC ducted systems Heating capacities from 0. Slip the heater into the duct and attach the back of the terminal box to the duct with sheet metal screws. Extended terminal pins to provide an unheated section adjacent to the heater terminal box. TPI HOT POD In-Line Duct Heater. All. FOR SLIP-IN TYPE HEATERS ONLY: (See Fig. However, the IDHE-O affords the installer the flexibility to position the offset on the left or right as Electrical duct heaters are designed for flange / Slip-in / Cylindrical in different duct connection mounting with climate control / heat generation and ventilation systems. is manufactured from fully galvanized sheets and is characterized by great stability of form and a smooth surface. 1 Single phase models only. Typically, Nailor Duct Heaters are derated to operate in the 40 to 60 watts per square inch of element surface density range. Some heaters are an integral part of other equipment, some have been approved for direct attachment to other equipment such as heat pumps, fans and variable air volume terminals, while others are approved for use as complete heating units to be mounted in air ducts. Slip & Drive Duct— The most common transverse (end to end) connection for commercial HVAC Duct. Derated Heating Coils improve heater element life and nuisance tripping. SALIENT FEATURES OF EDH. 4-Way Multi-positional. Unit Heaters. The following formulas can be used to determine the maximum kW for heater frame sizes. Open Coil Electric Duct Heaters are custom engineered to customer specification and built to order. Duct Heater Installation: The connection of the heater to the duct must be All heaters are maysuitable for installation with zero spacing between the duct and combustible surfaces. The entire heater except the terminal box slides through a rectangular opening in the side of the duct with 1/4" clearance all around. Designed to handle large volumes of air in residential and commercial HVAC applications, our electric duct heaters are installed into air handling systems and can be used as stand-alone solutions or as part of a larger multi-zone system. Inside duct dimensions and insulation thickness must be specified. TPI HOT POD In-Line Electric Duct Heater. Stock-Line slip-in type duct heaters are designed to meet most residential and light commercial requirements for use in forced air duct systems. View heater status and alarms remotely via network or thermostat; Remote monitoring (status, alarms, diagnostics, and trending) Wall-mount remote user interface (view temperature, setpoint, heater status Try changing the heater to flanged design which should help when you are at threshold of the maximum kW per square foot of a slip-in heater. Electric Duct Heater Owner’s Manual. Electric Duct Heaters are used for Space, Primary, Supplementary and Auxiliary heating applications. About This Product. ft. For slip-in heater applications where the insulation is more Price: $503. TPI HOT POD High Capacity In-Line Duct Heater. While power is disconnected, terminate all Duct sensor The DS-600 is a thermistor based duct sensor designed to work with Thermolec’s thermostats and electronic controllers to modulate the heater’s capacity according to the heat required. Maximum Heating Capacity: 1000 KW (single section) DUCT HEATERS UL & CSA LISTED ELECTRIC DUCT HEATERS STOCK- LINE SERIES • QUICKSILVER SERIES • CUSTOM BUILT SERIES WARREN T E C H N O L O G Y, I N C 2050 West 73 Street Hialeah, FL 33016 • Telephone: (305) 556 -6933 • Fax: (305) 557 -6157 Website: www. In addition, this heater is rated for slip in application only. Control voltage for above 24V. Heater Section available as Slip-In or Flanged Mount. Tank Heaters. The entire heater except the terminal box slides Typically, Nailor Duct Heaters are derated to operate in the 40 to 60 watts per square inch of element surface density range. Single Door control Box ; Insulated, Leakage proof Frame and Box styles. HP610001202T Markel Hotpod Heater. Nailor heaters may optionally be ordered with 35 or 25 watts per square inch element wire if ‘very low’ watt density is required. Approvals - Heaters and panelboards (if required) shall meet the requirements of the National Electrical Code and shall be listed by Underwriters Laboratories for zero clearance to combustible surfaces and for use with heat pumps and air conditioning Stock-Line (SL) Electric Duct Heaters. With clear instructions and detailed specifications, you'll have the confidence to maximize the performance and longevity of your Thermolec products. User Manual – Process Air Heaters. Nailor Electric Duct Heaters are self-contained heating units designed for installation in air handling systems. Instructions for Field Replacement of Resistance Open Coil Elements in Brasch Duct Heaters. Slip-in Heater: To install a slip-in heater (Figure 1), cut an opening as required in the side of the duct. They may be used as the primary source of heat or as supplementary or stand-by heat to Heat Pump, Gas or Oil Fired Systems. kW = Width X (Height – 2) X 0. Insert the heater and use the heater box as a template for the mounting screw locations. Slip Duct. com • E-Mail: warren@warrenhvac. S. To install INDEECO flanged duct heaters, flanges must be provided on the duct to match the heater flanges, both on the entering and leaving air sides. Slip-in type electric heater - Type I 1) Cut an opening in the duct. Slip the heater into the duct and attach the back of the terminal box to A PE switch controls the heater with a pneumatic air signal. Duct heaters shall be Heatrex: Type HUA Custom Slip-in Heater. The pick-up probe 20”. INDEECO QUA Open Coil Electric Duct Heaters for Commercial Heating Applications. 3) Secure electric Their applications vary from a partial or auxiliary nature to being the major or principal heat source in a building. 227 Series IOM. Coils in a flanged casing mount in air-handling units or to ductwork, while coils in a slip and drive casing can be directly connected to Warren offers custom duct and standard unitary slip-in heaters to meet electric heating specification and design requirements. 175mm) larger than the heater frame. Integrated HEC controller. Louis, Missouri and maintains two manufacturing facilities in the state. Several units may be used in a large duct or Redd-i Products Company has been supplying the HVAC industry with quality, affordable comfort systems for over 40. 2 product. Application. 4mm) flange on each side of the controlbox and can be attached directly to the duct with sheet metal screws. Instructions for Electric Duct Heaters with Type 3R Terminal Boxes. Most popular in the industry. Connect high and low voltage the duct to allow the heater to tightly slip in. Download the catalog and discover how Indeeco can meet your heating needs. One of the advantages of open coil heaters is that a number of similar heaters can be attached with one another to accommodate large duct size. UL and ETL Listed for use as a standalone heater. Consideration must be given to both airflow across the heater and the inlet temperature. Elements employ proprietary technology known as the “Calculated Wire Temperature Method" which insures optimum heater operation at the designed electrical and temperature requirements. The IDHE-O is a duct heater that is UL listed for outdoor applications. Duct Heaters 5 Slip In Heater It is designed so that the frame dimensions are slightly smaller than duct dimensions. Whether it’s cooling off a bedroom, adding airflow to a stuffy garage, or cooling off the entrance to a mall, Marley’s line of ventilation products has the answer. From Slip-in to Flanged Mounted Designs Indeeco has the heater for your application. Automatic reset prevents overheating. In this catalog, you can find detailed information about their duct heaters, including features, specifications, options, and accessories. Fresh Air Heater Today's airtight homes and offices beg for fresh air. the notes below. Offers best Duct to Heat Coverage. 9. Incorporated in 1957 as a manufacturer of electric heaters, Warren Technology has assumed a leading role within the HVAC industry Duct Heaters. Flanged heaters are designed so that the heater is an integral part of the duct work. They may be used as the primary source of heat or as supplementary or stand-by heat. warrenhvac. Ventilation. Standard Watt density of 30 kW/sqft. Slip In Heater It is designed so that the frame dimensions are slightly smaller than the duct dimensions. 2mm thickness Electro Galvanize steel plate, but can be made of other materials ( Stainless Steel Aluminium), if requested. Purchase Options: REQUEST A QUOTE Configure to Order. The Master Flow 16 in. For slip-in heater applications where the insulation is more In summary, the Quicksilver line offers the following to the customer: quick and easy pricing, UL-listed, slip-in type, 3 million combinations, 24-control volt only, up to 30 KW, magnetic de-energizing 24 volt contactors, circuit fusing over 48 amps per UL & NEC, control panel enclosure, duct sizes up to 36" x 20", 5-day production cycles, all The duct heater frame, con-trol enclosure and element support brackets shall be of 20 gauge (minimum) galvanized steel. Air Flow Requirements for ON-OFF Control The minimum air flow required through a duct heater depends on the KW per square foot of face area for the highest capacity ON-OFF INDEECO QUA Open Coil Electric Duct Heaters for Commercial Heating Applications. Remove unit and drill mounting holes. Apr 1, 2019 · The slip-into air duct heater inserts in the middle of the air flowing ventilation duct. This hole should be 1/8” larger than the heater frame. 4. 3. 3) Secure electric They are strategically placed and controlled for zone comfort heating. 2) 8. Thermolec In-Line 6" Electric Duct Heater - 2KW. sp ce fv zy ys ji eg jd qg wu